XCPC 4V220-06-DC24V Pneumatic Solenoid Valve (5/2-Way, Bistable, G1/8″, 24V DC)

XCPC 4V220-06-DC24V is a 5-port, 2-position (5/2) double solenoid (bistable) pneumatic directional control valve with internal pilot operation and G1/8″ ports. It is designed to switch compressed air flow and drive double-acting pneumatic cylinders in industrial automation systems.

1 People watching this product now!
Description

1. Purpose and Operating Principle

Operation is based on internal pilot spool actuation (Inner Guide Type) combined with bistable position memory:

  1. Prepared compressed air enters the supply port P (1) at an operating pressure of 0.15 to 0.8 MPa (1.5–8 bar).
  2. A short 24V DC impulse (minimum excitation time 0.05 s) on the first solenoid opens the pilot passage: supply air shifts the main aluminum spool into position 1 (air routed to outlet A (4), exhaust from B (2) through silencer port S (3)).
  3. Once power is removed from the coil, the spool holds its last switched position — continuous energization is not required. This prevents unintended cylinder return during a power outage and minimizes coil heat generation.
  4. Shifting to the second position occurs only when a 24V DC pulse is applied to the opposite coil (air routed to B (2), exhaust from A (4) through port R (5)).
  5. Built-in manual override buttons allow valve actuation without electrical power for commissioning, cylinder stroke testing, and troubleshooting.

2. Technical Specifications

Specifications are taken from the live product page at acvatron.md and the XCPC 4V technical catalog.

Parameter Value
Manufacturer XCPC
Model / Designation 4V220-06-DC24V
SKU (acvatron.md) 12976
Series 4V200
Valve Type 5/2-way (5 ports, 2 positions)
Control Scheme Double solenoid (bistable / memory function)
Motion Pattern Internal pilot (Inner Guide Type)
Port Threads (P / A / B / R / S) G1/8″ (BSPP, parallel)
Effective Sectional Area 14 mm² (Cv = 0.78)
Working Medium Compressed air, filtered to 40 µm or finer
Lubrication Not required (compatible with ISO VG32 oil mist)
Operating Pressure 0.15 – 0.8 MPa (1.5 – 8 bar)
Maximum Proof Pressure 1.2 MPa (12 bar)
Operating Temperature Range +5 … +50 °C
Coil Supply Voltage DC 24V (±10% tolerance)
Power Consumption 3.0 W (per energized coil)
Insulation & Protection Class Class F, IP65
Maximum Operating Frequency 5 cycles/sec (5 Hz)
Shortest Excitation Time 0.05 s
Spool & Internal Materials 6061 aluminum alloy (CNC-machined), POM internal guides, NBR seals
Manifold Mounting Compatible with 200M series manifold bases
Manual Override Built-in manual override buttons

3. Design Features

Part Number Breakdown: 4V220-06-DC24V (per XCPC 4V Catalog)

Code Position Symbol Meaning
Valve Family 4V 5-port solenoid directional control valve (2- or 3-position)
Body Size (Series) 2 200 Series (medium flow, 14 mm² effective area for 1/8″ ports)
Coils & Positions 20 Double solenoid, 2-position (5/2 bistable). Other options: 10 — single solenoid (5/2 monostable), 30C / 30E / 30P — 5/3 closed / exhaust / pressure center
Port Size 06 G1/8″ ports (08 — G1/4″ in 4V200 series)
Coil Voltage DC24V 24V DC (other catalog voltages: DC12V, AC24V, AC110V, AC220V, AC380V)
Wiring Form (blank) Standard DIN plug connector (options: LD / LD1 LED indicator connector, W — lead wire)

Key Engineering Solutions

  • Dual-Solenoid Bistable Design: the coil can be de-energized after switching while the spool mechanically retains its state — essential for clamping fixtures, lifters, and lines where a 24V power loss must not release the workpiece or retract the actuator.
  • Precision 6061 Aluminum Spool with POM Guides: CNC-machined spool surfaces paired with low-friction POM internal components and wear-resistant NBR seals deliver crisp 0.05 s response and oil-free operation.
  • IP65 Enclosure & Class F Insulation: dust-tight, water-jet-resistant coil assemblies allow direct machine-frame mounting in demanding industrial environments.
  • Manifold Modularity (200M Series): through-body mounting holes and standardized porting allow compact multi-station valve islands sharing common P supply and R/S exhaust galleries.
  • Integrated Manual Override: speeds up commissioning and mechanical testing before PLC wiring is live.

4. Installation Recommendations

  1. Port Thread Type and Proper Sealing (Critical):
    • BSPP (G1/8″, parallel — as on 4V220-06-DC24V): all five pneumatic ports (P, A, B, R, S) have parallel G1/8″ threads. Use parallel G1/8″ fittings with a flat face washer or captive O-ring — without PTFE tape.
    • BSPT (R1/8″, tapered — if tapered fittings are used): install with moderate torque using factory pre-coated sealant or PTFE tape (leaving the first 1–2 leading threads bare!), and never over-tighten into the aluminum valve body to prevent port cracking.
    • Metric parallel (on compact 4V100 valves with M5 ports): seal strictly with an O-ring at the thread base, without PTFE tape.
  2. Air Preparation and Exhaust Silencing:
    • Install an upstream FRL unit with 40 µm filtration or finer and condensate drainage. Note: once lubricated air (ISO VG32) is introduced into the valve, do not switch back to dry air because oil washes out the factory grease.
    • Always fit G1/8″ pneumatic silencers (or exhaust throttle silencers for cylinder speed control) into ports R (5) and S (3) to reduce noise and block abrasive shop dust from entering the spool bore.
  3. Maintain Minimum Pilot Pressure:
    • Because 4V220-06 is internally piloted, supply pressure at port P must stay above 0.15 MPa (1.5 bar) even during peak cylinder-start demand; otherwise the spool will fail to shift.
  4. 24V DC Electrical Wiring:
    • Never energize both solenoid coils simultaneously — enforce mutual exclusion in PLC logic or relay interlocking.
    • Keep power supply voltage within 24V DC ±10% (21.6–26.4 V). Use DIN connectors with built-in surge suppression (flyback diode/varistor) to protect PLC transistor outputs, and observe polarity if an LED diode module is fitted.
    • Verify that both manual override buttons are released before energizing the control system.

5. Equivalents and Comparison

Cross-Reference Table

Important: direct manifold footprint (200M) and body-dimension compatibility applies only to 4V200-standard valves (AirTAC, EMC, SHPI). SMC, Festo, Camozzi, and Metal Work models are functional equivalents (5/2 bistable, 1/8″ ports, 24V DC) with different footprints, mounting holes, and electrical connectors — verify mounting, thread standard (G1/8″ vs Rc1/8″), and coil inclusion before replacing.

Manufacturer Part Number / Model Function & Ports Voltage Compatibility Level
XCPC 4V220-06-DC24V 5/2 bistable, G1/8″ DC 24V Baseline model (14 mm², Cv = 0.78, 3.0 W)
AirTAC 4V220-06 (DC24V) 5/2 bistable, G1/8″ / PT1/8″ DC 24V Direct mechanical equivalent (fits 200M manifold; verify G/PT thread)
EMC / SHPI 4V220-06 (DC24V) 5/2 bistable, G1/8″ DC 24V Direct 4V200-standard equivalent
SMC SY5220-5LZD-01 / SY5220-5DZ-01 5/2 bistable, Rc1/8″ DC 24V Functional equivalent (different body, Rc1/8″ thread & connector)
SMC VFS2200-5FZ-01 5/2 bistable, Rc1/8″ DC 24V Heavy-duty functional equivalent (different footprint & manifold)
Festo VUVS-L20-B52-D-G18-F7-1C1 5/2 bistable (B52), G1/8″ DC 24V Modern VUVS functional equivalent (different footprint & manifold)
Festo JMFH-5-1/8-B (P/N 30486) 5/2 bistable, G1/8″ DC 24V (coils separate) Tiger Classic functional equivalent (do not confuse with monostable MFH-5-1/8!)
Camozzi 358-011-02 (Series 3) 5/2 bistable, G1/8″ DC 24V (Series U coils separate) Functional equivalent (~700 Nl/min, different footprint & manifold)
Metal Work 7010021200 (Series 70, SOV 25 SOB OO) 5/2 bistable, G1/8″ DC 24V (coils separate) Functional equivalent (~550 Nl/min, different footprint & manifold)

Comparison with Neighboring XCPC 4V Models

  • 4V210-06-DC24V (monostable, single solenoid): spring return resets the spool when power drops — choose when fail-safe retraction is required; choose 4V220-06-DC24V when position must be held during power loss.
  • 4V230C-06 / 4V230E-06 / 4V230P-06 (5/3-way, 3-position): adds a center position (closed C, exhaust E, or pressurized P) for mid-stroke cylinder stopping.
  • 4V220-08-DC24V (G1/4″ ports): same 200 series with larger G1/4″ ports for higher flow and larger cylinders.
  • 4V120-06-DC24V (100 Series): slimmer body with lower flow capacity (12 mm², Cv = 0.67, 2.5 W coil) for mini cylinders; 4V220-06 delivers higher flow (14 mm², Cv = 0.78).
  • 4V320-10 (300 Series, G3/8″ ports): for heavy Ø63–125 mm cylinders with high air consumption.

6. Common Mistakes

  1. Energizing both 24V coils at the same time: opposing pilot signals stall the spool in its prior state and overheat both coils. Always turn off the active PLC output before triggering the opposite coil.
  2. Operating with pressure dips below 1.5 bar (0.15 MPa): the internal pilot cannot shift the main spool, causing sluggish switching or continuous exhaust hiss.
  3. Wrapping PTFE tape onto parallel G1/8″ fittings: loose tape shreds migrate into fine pilot orifices, jamming the valve and causing constant exhaust leakage.
  4. Running without exhaust silencers in ports R and S: dust drawn back into open exhaust ports in woodworking, metalworking, or packaging environments rapidly wears NBR seals and seizes the spool.
  5. Leaving a manual override button locked down: electrical signals stop shifting the valve — frequently misdiagnosed as a burned-out solenoid coil.
  6. Omitting a filter/water trap (or operating below +5 °C): compressor condensate and oil emulsion gum up the pilot armature and corrode pilot springs.

7. Applications

The XCPC 4V220-06-DC24V valve drives double-acting pneumatic cylinders (ideally Ø20–50 mm bores) across industrial sectors:

  • packaging and filling machinery: gripping, sealing, cutting, and indexing actuators;
  • CNC machine tools and metalworking: workpiece clamps, safety doors, and tool changers (where power loss must not release clamped parts);
  • woodworking and furniture equipment: hold-down clamps, stops, and feed cylinders;
  • food and processing lines: dosing gates, diverters, and sorting mechanisms (in washdown-protected enclosures);
  • assembly lines and automation skids: multi-station 200M manifold valve banks controlled by 24V DC PLCs.

8. Expert Opinion

“Within the XCPC 200 series, the 4V220-06-DC24V is one of the best-balanced bistable valves for Ø25–50 mm cylinders. Its 14 mm² effective area (Cv = 0.78) and CNC-machined 6061 aluminum spool with POM guides deliver crisp 0.05 s switching up to 5 Hz, while the dual 24V DC coils hold clamps and actuators securely if power drops. Four habits guarantee long service life in the field: 40 µm filtered air, exhaust silencers in ports R and S, no PTFE tape on parallel G1/8″ ports, and software interlocking in the PLC so both coils are never powered together.”

Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience


9. FAQ — Frequently Asked Questions

1. What is the main difference between 4V220-06-DC24V and 4V210-06-DC24V? 4V210-06 is monostable (single coil with spring return) and automatically resets when power is removed. 4V220-06 is bistable (double solenoid): it switches on a brief 0.05 s pulse and keeps its position even if 24V power fails.

2. Can multiple 4V220-06 valves be mounted together on a manifold? Yes, 200-series valves mount directly onto standard 200M series manifold bases with shared P air supply and R/S exhaust channels. Unused stations are sealed with blanking plates.

3. Does 4V220-06-DC24V require lubricated air? No — it operates on clean, 40 µm filtered non-lubricated air thanks to factory grease and POM guides. If a lubricator is already installed in the line, use ISO VG32 turbine oil and maintain lubrication permanently, as oil flushes out factory grease.

4. Why won’t the valve shift at 1 bar supply pressure? 4V220-06 uses an internal pilot mechanism requiring a minimum supply pressure of 0.15 MPa (1.5 bar) at port P to shift the main spool reliably.

5. Can XCPC 4V220-06-DC24V replace an SMC, Festo, or Camozzi valve? For standalone inline mounting on tubing, 4V220-06 functionally replaces 5/2 bistable G1/8″ 24V DC valves (check flow capacity 14 mm² / Cv = 0.78 and adapt electrical connectors). It does not fit proprietary SMC/Festo/Camozzi manifold bases — direct manifold compatibility is strictly with 4V200-series valves (AirTAC, EMC, SHPI).

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “XCPC 4V220-06-DC24V Pneumatic Solenoid Valve (5/2-Way, Bistable, G1/8″, 24V DC)”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.