Heavy-Duty Industrial Piston Air Compressor SIGNAIR SC-500 LT100 (380 V, 500 L, 1400 l/min, 10 bar)

The SIGNAIR SC-500 LT100 heavy-duty belt-driven oil-lubricated industrial piston air compressor is engineered for continuous, uninterrupted compressed air supply at working pressures up to 10 bar (1.0 MPa) for large-scale production plants, industrial manufacturing workshops, automated assembly lines, spray-painting facilities, and commercial automotive fleet service centers. This unit is built as a 100% functional, dimensional, and structural analog of the European/Belarusian benchmark compressor Remeza (AirCast) СБ4/Ф-500.LT100.

6 People watching this product now!
Description

1. Purpose and Operating Principle

At the core of the machine is the heavy-duty cast-iron LT100 pump block — a four-cylinder, two-stage configuration arranged in a rigid V-formation (V4). The two-stage compression cycle provides superior thermodynamic efficiency and extended component service life:

  • First Stage (Low Pressure): Two oversized cylinders with a bore of ⌀105 mm draw atmospheric air through dual intake air filters to perform initial compression.
  • Interstage Cooling (Intercooler): The compressed, heated air is routed through a finned copper intercooler manifold, where it is cooled by the high-volume airflow drawn by the fan-bladed flywheel, lowering temperature and increasing air mass density.
  • Second Stage (High Pressure): Two smaller cylinders with a bore of ⌀55 mm receive the pre-cooled air and boost it to the final working pressure of 10 bar, passing through an aftercooler line into the receiver tank.

The low crankshaft operating speed (~850–900 rpm) driven by a 7.5 kW (10.0 HP, 380 V, 3-Phase) industrial electric motor minimizes mechanical friction, reduces piston ring wear, and ensures low operating temperatures. The heavy-gauge horizontal steel receiver with a capacity of 500 liters cushions pressure pulsations, stores an abundant volume of air for demanding pneumatic operations (sandblasting setups, 1″ heavy-duty impact wrenches, multi-gun paint booths), and accelerates moisture condensation.


2. Technical Specifications

Parameter Specification
Compressor Model SIGNAIR SC-500 LT100
Reference / Cross-Model Remeza СБ4/Ф-500.LT100 (AirCast Series)
Compressor Type Heavy-duty industrial piston, oil-lubricated, belt-driven
Pump Unit Type 4-cylinder, 2-stage, heavy-duty cast-iron block (LT100 type)
Cylinders / Compression Stages 4 (2 low-pressure + 2 high-pressure cylinders) / 2 stages
Cylinder Bore Diameter 1st Stage (LP): 2 × ⌀105 mm; 2nd Stage (HP): 2 × ⌀55 mm
Air Receiver Tank Volume 500 L (horizontal, stationary mounted on heavy-duty support brackets)
Inlet Air Displacement (Suction) 1400 l/min (1.4 m³/min)
Free Air Delivery (FAD / Output) ~1120 – 1180 l/min
Maximum Working Pressure 10 bar (1.0 MPa / 145 psi)
Cut-In Pressure (Pressure Switch Delta) 8 bar (0.8 MPa)
Rated Motor Power 7.5 kW (10.0 HP)
Electrical Power Supply 380–400 V / 50 Hz (3-Phase AC)
Pump Crankshaft Speed ~850–900 rpm
Pressure Control Assembly CONDOR MDR 3 (Germany) 3-phase pressure switch with thermal overload relay
Valve Reed Material Swedish SANDVIK 7C27Mo2 hardened valve spring steel
Cylinder Head Gaskets USA-made INTERFACE high-temperature non-asbestos composite
Piston Rings CYPR high-precision wear-resistant rings (⌀105 mm & ⌀55 mm)
Crankshaft Bearings C&U (heavy-duty precision radial bearings from C&U OEM facility)
Drive Belts SANLUX industrial-grade reinforced V-belts (B profile)
Pump & Tank Finish Eco-friendly water-based anti-corrosion paint
Outlet Air Connection G 3/4″ (BSPP) female thread ball valve
Crankcase Oil Capacity ~2.0 – 2.2 liters
Guaranteed Air Tank Lifespan 7–10 years (with regular daily condensate drainage)
Net Weight ~340 kg
Overall Dimensions (L×W×H) 2000 × 615 × 1250 mm

⚠️ Unconfirmed Parameters:

  • Electrical installation requirements: supplied without an electrical plug (requires hardwired installation into a distribution switchboard). A 5-core copper cable of at least 5×4.0 mm² and a 3-pole circuit breaker rated at 25 A (C or D curve) are recommended.
  • Initial factory oil grade: shipped with factory break-in oil. Complete oil drain and refill is recommended after the first 50 operating hours with dedicated ISO VG 100 / DIN 51506 VDL 100 piston compressor oil (Shell Corena S2 P 100, Mobil Rarus 427); KS-19 oils are not recommended.

3. Design and Engineering Features

Model Code Breakdown (SIGNAIR SC-500 LT100):

Code Segment Designation Engineering Description
SC Piston Compressor Series Heavy-duty professional reciprocating compressor series by SIGNAIR
500 Receiver Tank Size 500-liter welded heavy-gauge steel pressure vessel
LT100 Pump Unit Type 4-cylinder, 2-stage cast-iron pump block (2×⌀105 mm + 2×⌀55 mm)

SIGNAIR 7 Premium Components Checklist:

  1. USA-Made INTERFACE Cylinder Head Gaskets: In two-stage compression, high-pressure cylinder heads experience extreme thermal loads. The SC-500 LT100 uses authentic INTERFACE (USA) non-asbestos high-temperature composite gaskets. The material retains elasticity above +180 °C, preventing head-to-cylinder blow-by and micro-leakage.
  2. CYPR Precision Piston Rings: All four piston assemblies (both ⌀105 mm low-pressure and ⌀55 mm high-pressure) are equipped with rings manufactured by CYPR — a world-leading tier-1 engine and compressor OEM ring manufacturer. Precision ring gap geometry and alloy composition accelerate cylinder wall bedding, reducing friction and oil carryover.
  3. C&U Precision Crankshaft Bearings: The massive crankshaft is carried by high-capacity radial bearings manufactured on the OEM lines of the C&U facility. They easily support the continuous heavy radial tension exerted by the dual V-belts of the 7.5 kW motor, eliminating vibration and shaft deflection.
  4. Swedish SANDVIK 7C27Mo2 Valve Reeds: Valve reed plates on both stages are crafted from Swedish SANDVIK 7C27Mo2 flapper valve steel. The alloy provides unmatched fatigue resistance under millions of cyclic opening/closing cycles while retaining elasticity under high discharge temperatures, preventing valve reed edge chipping.
  5. SANLUX Reinforced V-Belts: Drive torque from the 7.5 kW motor is transmitted by industrial-grade SANLUX V-belts (B profile). Low-stretch polyester cords prevent slipping on the pulleys even during cold restarts under 8 bar residual backpressure.
  6. German CONDOR MDR 3 Switchgear: Automated control is handled by an authentic German CONDOR MDR 3 three-phase pressure switch. It includes an integrated, adjustable thermal overload relay to protect the motor from phase loss or overcurrent, and an unloader valve for smooth motor startup.
  7. Environmentally Friendly Water-Based Paint: The cast-iron pump, intercooler manifold, and crankcase are coated with eco-friendly water-based industrial paint. It provides heat and oil resistance without releasing volatile organic compounds (VOCs).

Factory Quality Control (QC) Standards:

  • 100% CNC Machined Crankcases: Bearing journals and cylinder mounting flanges are machined on multi-axis CNC centers, guaranteeing axial alignment and cylinder perpendicularity.
  • 2-Hour CMM Metrology Inspection: Finished crankcases are randomly sampled every two hours on a 3D Coordinate Measuring Machine (CMM) to confirm micron-level dimensional tolerances.
  • Dedicated Assembly Line: Assembly of the LT100 block is performed on a specialized production line utilizing calibrated torque wrenches.
  • 100% Pneumatic Leakage Testing: Every pump unit undergoes a pneumatic pressure leakage test before installation onto the air receiver.
  • 3-Minute Pump Run-In Test: Every bare pump unit runs on a testing bench for at least 3 minutes.
  • 5-Minute Complete Compressor Bench Test: Every fully assembled compressor unit (tank, motor, pump, controls) is tested under full 10-bar pressure for at least 5 minutes, checking pump-up time and pressure switch cut-out.
  • Durable 500-Liter Tank: The certified steel receiver features a guaranteed service life of 7–10 years when drained regularly.

4. Installation and Commissioning Guidelines

  • Electrical Connection (380 V, 3-Phase):
    • The 7.5 kW compressor must be hardwired into a dedicated industrial distribution board through a 3-pole circuit breaker rated at 25 A (C or D curve).
    • Power supply cabling must be copper with a minimum cross-section of 5×4.0 mm² (three phases, neutral, and protective earth PE).
    • ❗ Rotation Direction Verification (Phasing): Upon initial startup, check that the flywheel rotation strictly matches the arrow stamped on the belt guard. The flywheel blades must blow cooling air directly over the finned cylinders and the intercooler. If rotation is reversed, swap any two supply phases on the terminal block.
  • Foundation and Vibration Isolation:
    • With a net weight of 340 kg, the compressor must be placed on a level industrial concrete slab.
    • Do not rigidly anchor the support brackets directly into concrete without dampening pads. The unit must rest on heavy-duty rubber anti-vibration mountings.
  • Oil Level and Lubrication Requirements:
    • The LT100 crankcase requires ~2.0–2.2 liters of oil. Ensure the oil level is dead-center with the red indicator on the sight glass before startup.
    • Use exclusively certified reciprocating compressor oils meeting ISO VG 100 / DIN 51506 VDL 100 standards (such as Shell Corena S2 P 100 or Mobil Rarus 427).
    • ⛔ Strictly prohibited: automotive motor oils and substandard oils like KS-19. High discharge temperatures in the second stage cause oil oxidation and bake hard carbon onto the Sandvik valve reeds.
  • Break-In Procedure:
    • During the first 50 operating hours, run the compressor at a moderate duty cycle (duty factor under 60%).
    • At 50 hours, perform a complete oil drain and refill with fresh ISO VG 100 oil, and check the torque on all cylinder head bolts in a cross pattern on a cold pump. Subsequent oil changes should occur every 500 operating hours or annually.
  • Pneumatic Piping and Daily Drainage:
    • The discharge outlet features a G 3/4″ (BSPP) parallel female thread ball valve. Seal with a flat gasket.
    • The connection between the compressor and permanent steel workshop piping must be made using a flexible braided metallic vibration decoupler hose (at least 600–800 mm long).
    • At 1400 l/min air output, up to 5–10 liters of condensate can accumulate inside the 500L tank per shift. Open the bottom drain valve at the end of every working day (an automatic electronic timed drain is strongly recommended).
  • Compressor Room Ventilation:
    • Maintain at least 80–100 cm of clearance from adjacent walls. The room must have adequate ventilation to dissipate heat generated by the 7.5 kW motor and the LT100 pump.

5. Equivalents and Comparison

Comparative Analysis Table:

Parameter / Feature SIGNAIR SC-500 LT100 Remeza СБ4/Ф-500.LT100 Remeza СБ4/Ф-270.LT100 Remeza СБ4/Ф-500.LT100/16
Pump Unit Cast-iron LT100 (4-Cyl. / 2-Stg.) Cast-iron LT100 (4-Cyl. / 2-Stg.) Cast-iron LT100 (4-Cyl. / 2-Stg.) Cast-iron LT100 (4-Cyl. / 2-Stg.)
Receiver Volume 500 L 500 L 270 L 500 L
Motor Power 7.5 kW 7.5 kW 7.5 kW 11.0 kW (heavy-duty)
Supply Voltage 380 V (3-Phase) 380 V (3-Phase) 380 V (3-Phase) 380 V (3-Phase)
Inlet / Outlet Flow 1400 / ~1150 l/min 1400 / ~1150 l/min 1400 / ~1150 l/min 1400 / ~1050 l/min
Max Pressure 10 bar 10 bar 10 bar 16 bar (high pressure)
Head Gaskets INTERFACE (USA) Reinforced composite Reinforced composite Reinforced composite
Valve Reed Steel SANDVIK 7C27Mo2 (Sweden) Standard spring steel Standard spring steel Standard spring steel
Pressure Switch CONDOR MDR 3 (Germany) CONDOR MDR 3 / equivalent CONDOR MDR 3 CONDOR MDR 3
Parts Compatibility 100% Interchangeable Reference standard Reference standard Partial (pump only)

Key Advantages of SIGNAIR SC-500 LT100:

  • 100% Interchangeable Spare Parts: Valve plates, gaskets, pistons ⌀105/⌀55 mm, CYPR rings, connecting rods, crankshafts, and filters are fully compatible with Remeza LT100 parts catalogs.
  • Premium Industrial Wear Components: Incorporating American Interface gaskets and Swedish Sandvik valve steel provides enhanced endurance in multi-shift manufacturing environments.

6. Common Operating Mistakes

  1. Reverse Rotation (Incorrect Phasing): If supply phases are crossed, the flywheel rotates backwards and fails to cool the pump and intercooler. Within 20 minutes, pump temperature exceeds +220 °C, burning oil and seizing second-stage pistons.
  2. Neglecting Condensate Drainage in 500L Tank: Operating for months without draining allows 50–70 liters of rusty water to collect inside the receiver. This cuts usable air capacity, forces frequent motor cycling, and introduces water into air tools.
  3. Using Substandard Oil (KS-19 or Motor Oil): In a two-stage compressor, discharge air reaches high temperatures. Unsuitable mineral oils oxidize and build heavy carbon deposits on Sandvik valve reeds, slashing air output by half.
  4. Rigid Pipe Connection Without Vibration Hose: Rigid steel pipes bolted directly to the tank transmit machine vibration, leading to fatigue fractures at the tank’s threaded connection boss.
  5. Inadequate Ventilation in Compressor Room: Operating a 7.5 kW compressor in a small unventilated room creates a heat trap, causing the machine to overheat and trip the Condor thermal relay.

7. Applications

The SIGNAIR SC-500 LT100 compressor is designed for heavy industrial operations:

  • Commercial Fleet & Truck Service Centers: Powering 8–10 pneumatic bays simultaneously (3/4″ and 1″ heavy-duty impact wrenches, heavy commercial tire changers, air jacks).
  • Industrial Spray Painting Booths: Continuous air supply for multiple automated or manual paint booths utilizing HVLP/LVLP guns and air-driven sanders.
  • Sandblasting and Blast Cleaning Facilities: Delivering steady air volume for blast pots with 4–6 mm nozzles.
  • Metal Fabrication and Manufacturing: Supplying air for plasma and laser cutting machines (assist air), pneumatic presses, shears, and clamping fixtures.
  • Furniture and Woodworking Plants: Centralized air delivery for dozens of pneumatic nailers, staplers, and membrane presses.

8. Expert Opinion

«The LT100 pump unit is an absolute classic in heavy-duty reciprocating compressor design. Its two-stage compression scheme with 105 mm low-pressure cylinders and 55 mm high-pressure cylinders delivers a massive 1400 l/min displacement at a very low crankshaft speed of just 850–900 rpm.

In the SIGNAIR SC-500 LT100, we implemented 30 years of Acvatron SRL field engineering experience in Moldova. We eliminated all failure points: American Interface gaskets do not blow out under thermal load, Swedish Sandvik valve reeds resist cyclic fatigue, and genuine German Condor MDR 3 switchgear protects the 7.5 kW motor against overload.

Because this unit shares dimensions and parts with the Remeza СБ4/Ф-500.LT100, replacement parts are immediately available from our Chisinau inventory. For a factory, manufacturing shop, or commercial truck center, it represents the ideal choice for capacity, durability, and serviceability.»

— Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience


9. Frequently Asked Questions (FAQ)

1. Is the SIGNAIR SC-500 LT100 a complete replacement for the Remeza СБ4/Ф-500.LT100?

Yes, it is a 100% functional, dimensional, and parts equivalent. It features the identical two-stage cast-iron LT100 pump, 500-liter tank, 7.5 kW 380 V motor, and 1400 l/min displacement. All maintenance kits, pistons, valves, and filters are fully interchangeable.

2. What is the benefit of two-stage compression over single-stage?

In the LT100 pump, air is compressed progressively with interstage cooling: first in the ⌀105 mm cylinders, cooled in the intercooler manifold, and boosted in the ⌀55 mm cylinders. This prevents air overheating, enhances volumetric efficiency, and doubles valve and piston service life.

3. Which oil and capacity are required for the LT100 pump?

The LT100 crankcase takes ~2.0–2.2 liters of dedicated reciprocating compressor oil meeting ISO VG 100 / DIN 51506 VDL 100 standards (Shell Corena S2 P 100 or Mobil Rarus 427). Substandard oils like KS-19 and motor oils are strictly forbidden. The first change is at 50 hours, followed by changes every 500 hours.

4. What are the electrical wiring requirements?

A three-phase industrial 380–400 V (50 Hz) power supply is required. Wiring must be copper with a minimum cross-section of 5×4.0 mm² protected by a 25 A circuit breaker (C curve). Flywheel rotation direction must match the stamped arrow.

5. What is the expected service life of the 500-liter air receiver tank?

The heavy-duty steel receiver features a guaranteed operational life of 7–10 years, provided moisture condensate is drained daily through the bottom drain valve. For multi-shift operations, an automatic electronic timer drain is recommended.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Heavy-Duty Industrial Piston Air Compressor SIGNAIR SC-500 LT100 (380 V, 500 L, 1400 l/min, 10 bar)”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.