Gaoling L06Z-P55-8SC Oil-Free Scroll Compressor (5.5 kW, 8 bar, 600 L/min, 120 L)

The Gaoling L06Z-P55-8SC is a stationary industrial 5.5 kW (7.5 HP) oil-free scroll air compressor with a direct-drive permanent magnet synchronous motor (PMSM), mounted on a 120 L horizontal air receiver. Rated for 8 bar (0.8 MPa) working pressure, it delivers 600 L/min (0.60 m³/min / 36.0 m³/h) of 100% oil-free compressed air certified to ISO 8573-1 CLASS 0 (TÜV Rheinland).

2 People watching this product now!
Description

1. Purpose and Operating Principle

It is built for high-demand clean-air facilities — multi-chair dental clinics (up to 10–12 installed chairs), pharmaceutical manufacturing lines, analytical laboratories, hospital medical-gas plants, food processing, and wineries.

Compression principle (G06ZP scroll air end): No lubricating oil exists anywhere inside the G06ZP compression chamber. Air is compressed smoothly by two precision-machined involute scrolls — one stationary (Fixed Scroll) and one orbiting (Orbiting Scroll) offset by 180°. Driven by an eccentric shaft, the orbiting scroll runs with zero metal-to-metal contact while replaceable wear-resistant polymer Tip Seals seal the crescent compression pockets. Air moves continuously from the outer intake to the central discharge port without reciprocating impacts or pressure pulsations.

In the ZP series, the permanent magnet synchronous motor rotor and scroll element share a single shaft (direct drive, with no V-belts or pulleys). Operation, protection, and diagnostics are managed by the MAM-860 microprocessor controller with a 4-line LCD display, RS-485 / MODBUS-RTU communications, and multi-unit cascade control (BLOCK).


2. Technical Specifications

Parameter Value
Manufacturer Zhejiang Gaoling New Energy Technology Co., Ltd. (China)
Station Model Gaoling L06Z-P55-8SC
Scroll Air End G06ZP (ZP Series, PM Direct Connection)
Air Purity Class ISO 8573-1 CLASS 0 (TÜV Rheinland certified, 100% oil-free)
Rated Motor Power 5.5 kW (7.5 HP)
Motor Type Permanent Magnet Synchronous Motor (PMSM)
Drive Type Direct drive (beltless, coupling-free)
Power Supply AC 380 V, 3-phase, 50 Hz (3N AC 380V 50Hz)
Required Cable Size / Rated Current 4.0 mm² (Ø2.25 mm) / 32 A (per Instruction Manual, Table 1)
Working Pressure (Adjustment Range) 0.8 MPa / 8 bar (factory setting: load 0.60 MPa / unload 0.80 MPa)
Free Air Delivery (FAD, at 0.8 MPa) 0.60 m³/min (600 L/min / 36.0 m³/h)
G06ZP Air End Rated Speed 3150 rpm (at 0.8 MPa)
Controller MAM-860 microprocessor controller (LCD, RS-485 / MODBUS-RTU, Master/Slave cascade)
MAM-860 Protection Setpoints Over-temp: alarm 105 °C / trip 110 °C; over-pressure: trip 1.00 MPa; phase sequence protection (PHASE PRO)
Air Receiver Volume 120 L
Air Outlet G 1/2″ (BSPP female parallel thread)
Cooling System Forced air cooling via shaft-mounted Sirocco centrifugal fan
Condensate Drain Automatic electronic drainage valve (SC series standard)
G06ZP Air End Dimensions / Weight 500 × 387 × 343 mm / 42 kg
Compressor Module Dimensions / Weight (L06Z-P55-8, without tank) 680 × 560 × 888 mm / 119 kg (module noise: 63 dB(A))
Operating Ambient Temperature 0 °C … +40 °C (altitude ≤ 1000 m up to 50 °C; 1000–1500 m: 40 °C; 1500–3000 m: 35 °C)
Storage Temperature / Max Humidity −40 °C … +50 °C / ≤ 80%
Manufacturer & Product Certifications ISO 8573-1 CLASS 0 (TÜV Rheinland), CE (EN ISO 12100, EN 60204-1), ETL, ISO 9001, IATF 16949, ISO 14001, Class I Medical Instrument

3. Design Features

Model Code Breakdown: L06Z-P55-8SC

Code Element Meaning Explanation
L Station Line Gaoling oil-free scroll compressor stations
06 Air End Size G06ZP scroll element (5.5 kW nominal; 600 L/min at 8 bar / 505 L/min at 10 bar)
Z Drive Type Direct drive (Direct Connection), vs. T for belt drive
P55 Motor & Power Permanent Magnet (PM) synchronous motor, 55 = 5.5 kW
8 Working Pressure 8 bar (0.8 MPa)
SC Configuration Direct-drive PM station in acoustic canopy on a 120 L air receiver

Key Engineering Solutions

  • Integrated Scroll + PM Motor Monoblock (ZP Series): the G06ZP air end and PMSM motor share one shaft — eliminating V-belts, pulleys, and belt tensioning while cutting vibration and simplifying service.
  • MAM-860 Microprocessor Controller: 4-line LCD displays pressure, discharge temperature, supply voltage, total run hours, and load hours. Features built-in phase-sequence protection (PHASE PRO), high-temp shutdown at 110 °C, high-pressure trip at 1.00 MPa, remote start/stop (LOCAL/REMOTE), MODBUS-RTU (RS-485) communication, and BLOCK Master/Slave networking (up to 16 addresses) for multi-compressor sequencing.
  • Isolated Air Path (Tip Seal + Dust Seal): dry polymer tip seals keep compression chambers oil-free, while a dust barrier seal and external Grease Filling Port completely isolate bearing grease from the compressed air stream.
  • Directed Sirocco Air Cooling: draws cool air from the left side of the cabinet and exhausts hot air out the rear, making room ventilation straightforward to duct.
  • Automatic Electronic Drain & Safety Trim: comes standard with an electronic condensate drain valve, check valve (preventing air-end back-spin on shutdown), and receiver safety relief valve.

4. Installation Guidelines

(Based strictly on the official Gaoling Instruction Manual and Acvatron SRL field standards)

  1. Room & Service Clearances: indoor use only — install in a bright, clean, well-ventilated room at +2…+40 °C (manual specifies 0…+40 °C; keeping above +2 °C prevents drain freezing) and relative humidity ≤ 80%. Maintain at least 60 cm clearance on all sides for cooling and maintenance (and ≥ 60 cm between adjacent compressors). Respect airflow direction: intake on the left side, hot exhaust at the rear.
  2. Floor & Vibration Mounts: place on a hard, level floor strictly on its rubber vibration isolators (Rubber isolator), shimming with rubber pads if any gap exists. Remove all transport locking bolts/pins before initial start-up (Instruction Manual, Table 6).
  3. Electrical Wiring (5.5 kW, 380 V):
    • Connect to AC 380 V / 3-phase / 50 Hz with mandatory protective earthing.
    • Per Table 1 of the manual, 5.5 kW requires a minimum 4.0 mm² copper cable (2.25 mm conductor diameter) and a 32 A rated circuit breaker/line.
    • Verify phase sequence on commissioning (even with MAM-860 PHASE PRO enabled): reverse rotation exceeding 30 seconds can damage the scroll air end.
  4. Piping & Thread Connections:
    • Per Section 2.3.1 of the manual, heat- and pressure-resistant flexible hoses or metal piping connecting the compressor to external receivers/dryers/mains must have an internal diameter ≥ Ø25 mm, bend radius > 150 mm, pressure rating > 1.0 MPa, and heat resistance > 100 °C.
    • Seal the G 1/2″ (BSPP) female parallel outlet with a flat gasket or USIT / Bonded Seal washer — do not use PTFE tape (unlike tapered BSPT/R threads, which use PTFE tape, or metric parallel threads, which use a captive base O-ring).
  5. Medical & Pharmaceutical Air Treatment: Class 0 guarantees oil-free air, not dry or sterile air. Pair the receiver outlet with a refrigerated (+3 °C) or adsorption (−20 °C / −40 °C) dryer and particulate/sterile filtration matched to ISO 22052 or GMP.
  6. Commissioning & Safe Maintenance: fully open the outlet shut-off valve before starting. After sitting idle for more than 1 month, clear dust and perform a 1-minute test run. Surfaces reach scalding temperature within 10 minutes of running; before servicing, isolate power, depressurize completely to 0.00 MPa, and allow at least 30 minutes of natural cooling (never cool with water).

5. Equivalents and Comparison

Cross-Reference (5.5 kW / 8 bar Oil-Free Scroll Compressors)

Manufacturer & Model Power Pressure Flow (FAD) Air Purity Noise Configuration Notes
Gaoling L06Z-P55-8SC 5.5 kW 8 bar 600 L/min ISO 8573-1 Class 0 63 dB(A)* Direct-drive PM, 120 L tank, MAM-860 controller
Atlas Copco SF 6 (8 bar) 5.5 kW 8 bar 590 L/min (9.8 L/s) ISO 8573-1 Class 0 59 dB(A) Pack / FF (integrated dryer), opt. 270 L tank
Anest Iwata SLP-55F / SLPE-55F 5.5 kW 8 bar ~640 L/min ISO 8573-1 Class 0 (TÜV) 55 dB(A) Stationary acoustic enclosure, belt drive
BOGE EO 6 (8 bar) 5.5 kW 8 bar 620 L/min (10.33 L/s) ISO 8573-1 Class 0 62 dB(A) Base cabinet, receiver (R), or dryer (D)
Remeza KS7-8 / KS7-8-270 5.5 kW 8 bar 605 L/min (520–602 in M/D builds) ISO 8573-1 Class 0 64 dB(A) Frame (КС7-8) or 270 L tank (КС7-8-270), opt. M/D dryers

*63 dB(A) verified for base module L06Z-P55-8. Always confirm receiver volume, footprint, outlet thread, dryer integration, and service intervals before cross-brand substitution.

Comparison Within the Gaoling Lineup (01/2026 Catalog)

Model Power Pressure Flow (FAD) Configuration Weight Noise
L05Z-P37-8SC 3.7 kW 8 bar 400 L/min Direct PM, 120 L receiver 174 kg 65 dB(A)
L06Z-P55-8 5.5 kW 8 bar 600 L/min Direct PM, cabinet without tank 119 kg 63 dB(A)
L06Z-P55-8SC 5.5 kW 8 bar 600 L/min Direct PM, 120 L receiver — 63 dB(A)*
L06Z-P55-8LR 5.5 kW 8 bar 570 L/min All-in-One: 200 L tank + refrig. dryer 267 kg 65 dB(A)
L06Z-P110-8 11 kW (5.5×2) 8 bar 1200 L/min Dual PM scroll cabinet, no tank 258 kg 64 dB(A)

Why a 5.5 kW Gaoling scroll outperforms oil-injected screw and oil-free piston units in this class:

  • vs. 5.5 kW Oil-Injected Screw: 100% oil-free Class 0 air with zero separator-breakthrough risk to dental handpieces or pharmaceuticals; eliminates oil, oil filters, separators, and oily-condensate disposal; avoids oil emulsification under fluctuating clinic demand.
  • vs. Oil-Free Piston (PTFE): true 24/7 continuous duty with no cool-down pauses, far quieter (63 dB(A) vs. 78–85+ dB(A) for 5.5 kW pistons), pulsation-free delivery, and much longer seal life (5000 h Tip Seals vs. 1000–2500 h PTFE rings).

6. Common Mistakes

  1. Sizing a clinic or pharma line to the full 600 L/min with zero safety margin. Without a 20–30% buffer for filter/piping drops and desiccant dryer purge air (12–15% for heatless dryers), line pressure will sag below 5–6 bar at peak demand.
  2. Wiring 5.5 kW with a 2.5 mm² cable or 16–20 A breaker instead of 4.0 mm² / 32 A. Table 1 of the manual specifies 4.0 mm² and 32 A at 380 V; undersized wiring causes voltage drop, contactor heating, and nuisance overload trips.
  3. Using an undersized discharge hose (< Ø25 mm I.D.) to an external tank or dryer. Section 2.3.1 mandates ≥ Ø25 mm I.D. and bend radius > 150 mm — choking the discharge line creates back-pressure and high-temperature trips.
  4. Skipping the 2500 h air filter change or 5000 h Tip Seal + bearing grease service. Per Table 5, blow off the filter at 400 h and 1500 h, replace it at 2500 h / 1 year, and replace Tip Seals + add fresh bearing grease strictly at 5000 h / 2 years.
  5. Pushing the cabinet against a wall (< 60 cm clearance) or into an unventilated closet. Heat rejected by the 5.5 kW motor quickly triggers the MAM-860 high-temp alarm (105 °C) and shutdown (110 °C).
  6. Omitting dryers and sterile filters in dental and pharma installations. Class 0 oil purity does not remove moisture or microbes — downstream drying and filtration per ISO 22052 / GMP are mandatory.

7. Applications (Exact Engineering Sizing at 600 L/min)

With a rated FAD of 600 L/min (36.0 m³/h) at 8 bar, the recommended continuous design load with a 20–25% engineering margin (covering filter/piping losses and dryer purge) is 450–480 L/min.

Application Sizing Table

Industry & Equipment Typical Demand per Unit (Industry Benchmarks) Real Capacity of L06Z-P55-8SC (600 L/min) Required Downstream Air Treatment
Dental Clinic (Dental Chairs / Units) 50–60 L/min per active chair at 5 bar (ISO 7494 / Dürr Dental / Cattani benchmark; 70+ L/min with Air-Flow or CAD/CAM) 8–9 chairs operating simultaneously (with 20–25% margin) → 10–12 total installed chairs (at 0.65–0.75 coincidence factor; up to 10 simultaneous chairs with zero margin) Air dryer (≤ +3 °C or −20 °C PDP) + bacterial/particulate filter per ISO 22052
Pharmaceutical: Tablet Dedusters 50–200 L/min at 4–6 bar (pulsed/jet cleaning) 2–3 machines simultaneously with margin Desiccant dryer (−40 °C to −70 °C PDP) + 0.01 µm sterile filters (GMP / ISO 8573-1)
Pharmaceutical: Capsule Filling Machines 300–800 L/min at 6 bar 1 medium-speed filler (up to ~450 L/min) Desiccant dryer (−40 °C) + sterile filtration, 316L stainless steel piping
Pharmaceutical: Blister Packaging Lines 400–1200 L/min at 6–7 bar 1 compact / medium-speed line (up to ~450 L/min; choose L06Z-P110-8 for 800–1200 L/min high-speed lines) Desiccant dryer (−40 °C) + fine filtration
Laboratories & PSA Nitrogen Generators Chromatographs/analyzers: 10–30 L/min; PSA N₂ generator (99–99.5%): ~3–4:1 air-to-N₂ ratio Multiple lab instruments or a PSA nitrogen generator up to ~120–160 L/min N₂ Refrigerated or desiccant dryer + particulate/carbon filter
Food Processing & Winemaking Bottling, capping, labeling, MAP packaging lines 1–2 production lines totaling up to 450–500 L/min Refrigerated dryer (+3 °C) + particulate line filters
  • High-speed pharmaceutical lines or 15+ chair clinics exceeding 500–550 L/min simultaneous draw: upgrade to the dual-scroll L06Z-P110-8 (11 kW, 1200 L/min, built-in redundancy) or sequence two L06Z-P55-8SC units via MAM-860 (BLOCK Master/Slave).
  • Processes requiring 8.5–10 bar: select the 10 bar variant (G06ZP delivers 505 L/min at 10 bar).
  • Unheated or dusty areas (below 0…+2 °C, abrasive dust, solvent vapors).

8. Expert Opinion

Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience: “The Gaoling L06Z-P55-8SC built around the G06ZP air end bridges the gap from small point-of-use units to a true central clean-air plant. A verified 600 L/min at 8 bar safely powers a busy 10–12 chair dental clinic (8–9 chairs running simultaneously with engineering headroom) or dedicated pharmaceutical equipment such as tablet dedusters or a medium-speed capsule/blister machine. Another standout is the MAM-860 controller: built-in phase protection, high-temperature shutdown, and RS-485 Master/Slave cascading make it simple to add a second redundant unit as your clinic or plant grows. For medical and GMP sites, we always supply it as a complete package with matched drying and sterile filtration.”


9. FAQ

1. How many dental chairs can the Gaoling L06Z-P55-8SC support? Using the industry benchmark of 50–60 L/min per active chair at 5 bar, its 600 L/min output with a proper 20–25% safety margin handles 8–9 chairs running simultaneously — covering a 10–12 chair dental clinic at a typical 0.65–0.75 coincidence factor (paired with an ISO 22052 dryer and filters).

2. Is the L06Z-P55-8SC suitable for pharmaceutical manufacturing (GMP)? Yes, as a certified ISO 8573-1 CLASS 0 oil-free air source (TÜV Rheinland; manufacturer holds Class I Medical Instrument registration). For direct product contact under EU GMP Annex 1, add a desiccant dryer (−40 °C to −70 °C PDP), sterile filtration, and 316L stainless-steel distribution piping.

3. What cable size and circuit breaker are required for 5.5 kW? Per Table 1 of the official Gaoling Instruction Manual, the 3-phase 5.5 kW (AC 380 V / 50 Hz) station requires at least a 4.0 mm² copper supply cable (2.25 mm diameter), a 32 A rated circuit breaker, and mandatory grounding.

4. What is the exact maintenance schedule specified in the Gaoling manual? Per Table 5 of the manual: drain condensate daily; blow off air-filter dust every 400 h / 2 months and 1500 h / 6 months; replace the air filter element and inspect valves/sensors every 2500 h / 1 year; replace the Tip Seal kit and add fresh bearing grease every 5000 h / 2 years; replace rubber isolators and the safety relief valve at 10,000 h / 4 years.

5. Can two Gaoling L06Z-P55-8SC units be cascaded for redundancy? Yes. The standard MAM-860 controller supports BLOCK (Master / Slave) networking over RS-485 (up to 16 addresses) with automatic duty rotation (TURN TIME) and peak-load staging — ideal for 24/7 clinics and pharmaceutical facilities.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Gaoling L06Z-P55-8SC Oil-Free Scroll Compressor (5.5 kW, 8 bar, 600 L/min, 120 L)”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.