Gaoling L06Z-P110-10LR All-in-One Oil-Free Scroll Compressor (11 kW, 10 bar, 1000 L/min, 300 L, Refrigerated Dryer)

The Gaoling L06Z-P110-10LR is a turnkey All-in-One oil-free scroll air compressor station rated at 11 kW (2 × 5.5 kW / 15 HP), combining two independent direct-drive PM G06ZP scroll air ends, an integrated refrigerated air dryer, a line filter, and a 300 L horizontal air receiver with an automatic electronic condensate drain. Engineered for 10 bar (1.0 MPa) working pressure, it delivers 1000 L/min (1.0 m³/min / 60.0 m³/h) of dry, 100% oil-free air certified to ISO 8573-1 CLASS 0 (TÜV Rheinland).

5 People watching this product now!
Description

1. Purpose and Operating Principle

Its dual-module 5.5 kW × 2 architecture addresses two critical industrial and clinical requirements simultaneously:

  1. Staged Energy Efficiency (0 / 50% / 100%): under partial demand only one 5.5 kW module (500 L/min) runs while the second stages in automatically at peak demand — avoiding wasted no-load power.
  2. Built-in 50% Redundancy: during scheduled maintenance or a fault on one module, the second G06ZP air end keeps supplying up to 500 L/min at 10 bar, preventing unplanned shutdowns of clinics or production lines.

Compression principle (G06ZP air ends): No oil exists inside either compression chamber. Each air end pairs a stationary (Fixed Scroll) and orbiting (Orbiting Scroll) involute scroll offset by 180° with zero metal-to-metal contact; sealing is maintained by replaceable dry polymer Tip Seals. Permanent magnet synchronous motors (PMSM) drive each air end directly on a single shaft (2800 rpm at 10 bar) with no belts or pulleys. Discharge air cools, enters the 300 L receiver, and flows through the integrated refrigerated dryer and filter before leaving the station.


2. Technical Specifications

Parameter Value
Manufacturer Zhejiang Gaoling New Energy Technology Co., Ltd. (China)
Station Model Gaoling L06Z-P110-10LR (All-in-One)
Scroll Air Ends 2 × G06ZP (ZP Series, PM Direct Connection)
Air Purity Class ISO 8573-1 CLASS 0 (TÜV Rheinland certified, 100% oil-free)
Rated Motor Power 11 kW (5.5 kW × 2) / 15 HP
Motor Type 2 × Permanent Magnet Synchronous Motor (PMSM)
Drive Type Direct drive (beltless, coupling-free)
Power Supply AC 380 V, 3-phase, 50 Hz (3N AC 380V 50Hz)
Rated Working Pressure 1.0 MPa (10 bar)
Free Air Delivery (FAD, at 10 bar) 1.0 m³/min (1000 L/min / 60.0 m³/h)
Air End Rated Speed 2800 rpm (at 1.0 MPa)
Integrated Air Treatment Refrigerated air dryer (LR) + line filter
Air Receiver Volume 300 L
Air Outlet G 1″ (BSPP female parallel thread)
Control System Automatic pressure-sensitive control, MAM-860 controller (RS-485 / MODBUS-RTU)
Cooling System Forced air cooling, Sirocco centrifugal fans
Condensate Drain Automatic electronic drainage valve (standard)
Noise Level 65 dB(A)
Dimensions (L × W × H) 1652 × 700 × 1930 mm
Net Weight 494 kg
Operating Ambient Temp / Humidity 0 °C … +40 °C (recommended +5…+40 °C) / ≤ 80%
Manufacturer & Product Certifications ISO 8573-1 CLASS 0 (TÜV Rheinland), CE (EN ISO 12100, EN 60204-1), ETL, ISO 9001, IATF 16949, ISO 14001, Class I Medical Instrument

3. Design Features

Model Code Breakdown: L06Z-P110-10LR

Code Element Meaning Explanation
L Station Line Gaoling oil-free scroll compressor stations
06 Air End Size G06ZP scroll elements (5.5 kW each; 505 L/min per element at 10 bar)
Z Drive Type Direct drive (Direct Connection), vs. T for belt drive
P110 Motors & Total Power Permanent Magnet (PM) synchronous motors, 110 = 11.0 kW (5.5 kW × 2)
10 Working Pressure 10 bar (1.0 MPa)
LR All-in-One Package Compressor + 300 L tank + refrigerated air dryer (LR) + filter (vs. LD with adsorption dryer)

Key Engineering Solutions

  • Dual Independent Direct-Drive G06ZP Modules (5.5 kW × 2): demand-based staging, balanced run-hour alternation, and 50% built-in redundancy inside a single footprint — with zero belt maintenance.
  • Factory-Piped All-in-One Package on a 300 L Receiver: scroll cabinet, refrigerated air dryer, and line filter come pre-plumbed and factory-tested on one frame — saving up to 40% compressor-room floor space and slashing on-site installation time.
  • MAM-860 Microprocessor Controller: 4-line LCD display, automatic load/unload staging, phase-sequence protection (PHASE PRO), high-temp protection (105 °C alarm / 110 °C trip), remote start/stop (LOCAL/REMOTE), MODBUS-RTU (RS-485) communications, and BLOCK network cascading.
  • Sealed Air Path (Tip Seal + Dust Seal): bearings remain isolated from compression chambers and are regreased via dedicated external Grease Filling Ports.
  • Automatic Electronic Drain: discharges clean oil-free condensate automatically from the 300 L receiver and dryer separator.

4. Installation Guidelines

(Based on the official Gaoling Instruction Manual and Acvatron SRL engineering practice)

  1. Room & Ventilation: indoor installation only at +5…+40 °C (below 0 °C condensate freezes inside the refrigerated dryer heat exchanger and electronic drain) and relative humidity ≤ 80%. Because the combined 11 kW drive plus refrigerated dryer rejects substantial heat, dedicated intake/exhaust ventilation is essential. Leave at least 60–100 cm service clearance all around (intake on left, hot exhaust at rear).
  2. Foundation & Rigging: net weight is 494 kg, height 1930 mm. Place on a solid, level concrete slab strictly on the supplied rubber vibration isolators (Rubber isolator) and remove all transport locking bolts before commissioning.
  3. Electrical Connection (11 kW, AC 380 V, 3-Phase):
    • Supply from 3N AC 380 V / 50 Hz through a dedicated circuit breaker with mandatory protective earthing (size cable and breaker for 2 × 5.5 kW plus the integrated refrigerated dryer).
    • Verify phase sequence at first start-up (even with MAM-860 PHASE PRO active): reverse rotation exceeding 30 seconds can damage the scroll elements.
  4. Pneumatic Piping (G 1″ BSPP Outlet):
    • The station air outlet is a G 1″ (BSPP) female parallel thread. Seal using a flat gasket or USIT / Bonded Seal washer — do not use PTFE tape (unlike tapered BSPT/R threads, which require PTFE tape, or metric parallel threads with a base O-ring).
    • Connect to plant mains via a heat- and pressure-resistant flexible hose (for 10 bar machines, Section 2.3.1 of the manual requires > 1.2 MPa pressure rating, ≥ Ø25 mm internal diameter, > 150 mm bend radius, and > 100 °C heat resistance).
  5. Condensate Drainage: pipe drain lines from both the 300 L receiver electronic valve and the refrigerated dryer drain to a floor drain — oil-free condensate needs no oil-water separator.
  6. Safe Maintenance: isolate main power, depressurize to 0.00 MPa, and allow at least 30 minutes of natural cooling before servicing (never cool with water).

5. Equivalents and Comparison

Cross-Reference (11 kW / 10 bar Oil-Free Scroll Compressors)

Manufacturer & Model Power Pressure Flow (FAD) Air Purity Noise Configuration Notes
Gaoling L06Z-P110-10LR 11 kW (2×5.5) 10 bar 1000 L/min (1.0 m³/min) ISO 8573-1 Class 0 (TÜV) 65 dB(A) All-in-One: dual PM blocks + 300 L tank + refrig. dryer + filter
Atlas Copco SF 11+ FF (10 bar) 11 kW (15 HP) 10 bar 900 L/min (0.90 m³/min) ISO 8573-1 Class 0 63 dB(A) FF Full Feature with integrated refrigerated dryer
BOGE EO 11 D (10 bar) 11 kW (2×5.5) 10 bar 980 L/min (0.98 m³/min) ISO 8573-1 Class 0 59–65 dB(A) Dual scroll + refrigerated dryer (D), optional receiver
Anest Iwata SLPE-1101E 11 kW (3×3.7) 10 bar 1009 L/min (1.01 m³/min) Oil-free (Scroll) 60–62 dB(A) Triple belt-driven multi-scroll, optional dryer (D)

Important before substituting: verify footprint, whether a 300 L receiver is included (often sold separately by European brands), outlet thread (G 1″), dryer dew point, and maintenance intervals.

Comparison Within the Gaoling All-in-One LR Lineup (01/2026 Catalog)

Model Power Pressure Flow (FAD) Dryer / Tank Outlet Dimensions (mm) Weight Noise
L06Z-P55-8LR 5.5 kW 8 / 10 bar 570 / 500 L/min Refrig. dryer + 200 L G 3/4″ 1375 × 560 × 1518 267 kg 65 dB(A)
L05Z-P75-8LR 7.5 kW (3.7×2) 8 / 10 bar 760 / 700 L/min Refrig. dryer + 300 L G 1″ 1652 × 700 × 1930 371 kg 65 dB(A)
L06Z-P110-10LR 11 kW (5.5×2) 10 bar 1000 L/min Refrig. dryer + 300 L G 1″ 1652 × 700 × 1930 494 kg 65 dB(A)
L06Z-P165-8LR 16.5 kW (5.5×3) 8 / 10 bar 1710 / 1500 L/min Refrig. dryer + 300 L G 1″ 2180 × 760 × 2380 590 kg 69 dB(A)
L06T-Y110-8LR 11 kW (5.5×2, belt) 8 / 10 bar 1140 / 1000 L/min Refrig. dryer + 300 L G 1″ 1692 × 760 × 1934 495 kg 68 dB(A)

(Note: the direct-drive PM L06Z-P110-10LR runs 3 dB(A) quieter than the belt-driven L06T-Y110-8LR, takes less space, and requires zero belt replacements.)

Advantages over 11 kW oil-injected screw and oil-free piston compressors:

  • vs. 11 kW Oil-Injected Screw: guaranteed Class 0 oil-free air with zero separator-breakthrough risk and without the 0.5–1.2 bar pressure loss of oil-removal/carbon filter cascades; zero oil, oil filter, separator, or oily-condensate disposal costs; staged 50% / 100% dual-scroll operation avoids idle power waste and oil emulsification.
  • vs. Oil-Free Piston: true 24/7 duty at 10 bar without overheating, quiet 65 dB(A) operation (vs. 80–88 dB(A) for 11 kW pistons), pulsation-free air, and 5000 h Tip Seal intervals vs. 1000–2500 h for PTFE piston rings.

6. Common Mistakes

  1. Installing an 11 kW + refrigerated dryer package in a tight, unventilated room. Heat rejected by two 5.5 kW motors and the dryer condenser quickly pushes room temperature above +40 °C — degrading dew point and tripping the MAM-860 high-temp alarm (110 °C).
  2. Running the refrigerated dryer below +2…+5 °C. Water freezes inside the dryer heat exchanger and electronic drain, risking heat-exchanger rupture.
  3. Relying on the built-in refrigerated dryer (LR) where GMP mandates −40 °C dew point. Refrigerated dryers operate physically above 0 °C (ISO 8573-1 Class 4). Direct contact with hygroscopic pharma powders or outdoor winter lines requires an adsorption dryer (LD version or external desiccant dryer).
  4. Servicing only one air end or skipping the 5000 h overhaul (Tip Seal + bearing grease). Both G06ZP modules require scheduled care: filter cleaning at 400 h and 1500 h, filter replacement at 2500 h / 1 year, and Tip Seal replacement + bearing regreasing at 5000 h / 2 years.
  5. Using an undersized (< Ø25 mm) or under-rated discharge hose. For a 10 bar / 1000 L/min station, Section 2.3.1 mandates ≥ Ø25 mm I.D. and > 1.2 MPa hose rating.
  6. Neglecting condenser and air-cooler dust cleaning. Dust-fouled dryer condenser fins reduce cooling capacity and allow moisture carryover downstream.

7. Applications (Exact Engineering Sizing at 1000 L/min, 10 bar)

At 1000 L/min (60.0 m³/h) at 10 bar, the continuous design load with a 20–25% engineering margin is 750–800 L/min of pre-dried, 100% oil-free compressed air.

Industry Sizing Table

Industry & Equipment Typical Demand per Unit (Benchmarks) Capacity of L06Z-P110-10LR (1000 L/min, 10 bar) Additional Notes
Large Dental Clinic / Medical Center (Chairs) 50–60 L/min per active chair at 5 bar (ISO 7494 / Dürr Dental / Cattani; 70+ L/min with Air-Flow / CAD/CAM) 13–15 chairs simultaneously (with 20–25% margin) → 16–20 installed chairs (0.70–0.75 coincidence factor). Built-in 50% backup (500 L/min on one air end) Refrigerated dryer is built in (LR); add an ISO 22052 bacterial/sterile filter
Pharmaceutical (GMP): Blister, Capsule & Dedusting Lines Deduster: 50–200 L/min; capsule filler: 300–800 L/min; blister line: 400–1200 L/min (6–7 bar) 1 high-output blister or capsule machine (up to ~750–800 L/min) or 1 capsule filler + 2–3 dedusters simultaneously For direct drug contact under GMP: add adsorption dryer (−40…−70 °C PDP) + 0.01 µm sterile filters & 316L piping
PSA Nitrogen Generators (Wineries, MAP Packaging, Electronics) Air-to-N₂ ratio ~3–4:1 at 99–99.5% N₂ purity and 8–10 bar Feeds a PSA generator rated up to ~220–280 L/min N₂ (13–17 m³/h N₂) Dry Class 0 air straight from the station; match dew point for 99.99% N₂ units
Small PET Blowing, CNC Clamping & Laser Cutting (8.5–9.5 bar) High-pressure actuators, optics purging, forming stations Holds steady 8.5–9.5 bar at point of use up to 750–800 L/min despite line drops Add fine particulate filtration per machine OEM spec
Food Processing & Winemaking Bottling, capping, labeling, pneumatic conveying 2–3 production lines totaling 750–800 L/min Turnkey package (300 L tank + dryer + filter built in)
  • Continuous demand above 850–900 L/min at 10 bar: step up to the triple-scroll All-in-One L06Z-P165-8LR (16.5 kW, 1500 L/min at 10 bar) or modular L06Z-P220-8 / L06Z-P330-8 stations.
  • 8 bar plants prioritizing maximum flow at 11 kW: the 8 bar L06Z-P110-8LR delivers 1140 L/min (+140 L/min).
  • Sub-freezing spaces (< +2 °C) or chemically aggressive/explosive environments.

8. Expert Opinion

Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience: “The Gaoling L06Z-P110-10LR is a complete central clean-air plant in one footprint: two independent 5.5 kW G06ZP scroll modules, a 300 L receiver, a refrigerated dryer, and a line filter. For a 16–20 chair dental center, a pharmaceutical packaging room, or a winery running a PSA nitrogen generator, the real value goes beyond its verified 1000 L/min at 10 bar and TÜV Rheinland Class 0 certificate — it is built-in redundancy. Take one air end offline for maintenance and the second keeps feeding 500 L/min without stopping operations. Just make sure the compressor room has proper exhaust ventilation for 11 kW plus dryer heat, and let us add a desiccant dryer and sterile filtration if your GMP protocol specifies −40 °C dew point.”


9. FAQ

1. Why are two 5.5 kW air ends better than a single 11 kW compressor? Two independent G06ZP blocks deliver staged 50% / 100% power savings at partial load and 50% built-in redundancy: during maintenance or a fault on one unit, the second keeps supplying 500 L/min at 10 bar so the clinic or plant never goes down.

2. How many dental chairs can the Gaoling L06Z-P110-10LR run? At 50–60 L/min per chair at 5 bar with a 20–25% engineering margin, it powers 13–15 chairs simultaneously, covering a large 16–20 chair dental clinic at a 0.70–0.75 coincidence factor (refrigerated dryer is built in; add an ISO 22052 bacterial filter).

3. Do I need an extra dryer if the L06Z-P110-10LR already includes a refrigerated dryer? For dental clinics, food/wine lines, CNC, and indoor automation, the built-in LR refrigerated dryer is sufficient. An additional adsorption dryer (−40 °C to −70 °C PDP) is only needed for direct GMP contact with hygroscopic pharmaceuticals or outdoor winter piping.

4. What is the maintenance schedule for the Gaoling L06Z-P110-10LR? Daily condensate/drain check; air filter dust cleaning at 400 h and 1500 h; air filter replacement, cooler cleaning, and valve/sensor inspection at 2500 h / 1 year; Tip Seal replacement and bearing regreasing on each block every 5000 h / 2 years; rubber isolators and safety relief valve replacement at 10,000 h / 4 years.

5. What is the difference between L06Z-P110-10LR and L06Z-P110-8LR? Both share the same chassis (2 × 5.5 kW, 300 L tank, refrigerated dryer, 494 kg, 65 dB(A)). The 10LR runs at 10 bar (2800 rpm) delivering 1000 L/min, while the 8LR runs at 8 bar delivering 1140 L/min.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Gaoling L06Z-P110-10LR All-in-One Oil-Free Scroll Compressor (11 kW, 10 bar, 1000 L/min, 300 L, Refrigerated Dryer)”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.