Gaoling L06Z-P110-10LR All-in-One Oil-Free Scroll Compressor (11 kW, 10 bar, 1000 L/min, 300 L, Refrigerated Dryer)
The Gaoling L06Z-P110-10LR is a turnkey All-in-One oil-free scroll air compressor station rated at 11 kW (2 × 5.5 kW / 15 HP), combining two independent direct-drive PM G06ZP scroll air ends, an integrated refrigerated air dryer, a line filter, and a 300 L horizontal air receiver with an automatic electronic condensate drain. Engineered for 10 bar (1.0 MPa) working pressure, it delivers 1000 L/min (1.0 m³/min / 60.0 m³/h) of dry, 100% oil-free air certified to ISO 8573-1 CLASS 0 (TÜV Rheinland).
1. Purpose and Operating Principle
Its dual-module 5.5 kW × 2 architecture addresses two critical industrial and clinical requirements simultaneously:
- Staged Energy Efficiency (0 / 50% / 100%): under partial demand only one 5.5 kW module (500 L/min) runs while the second stages in automatically at peak demand — avoiding wasted no-load power.
- Built-in 50% Redundancy: during scheduled maintenance or a fault on one module, the second
G06ZPair end keeps supplying up to 500 L/min at 10 bar, preventing unplanned shutdowns of clinics or production lines.
Compression principle (G06ZP air ends): No oil exists inside either compression chamber. Each air end pairs a stationary (Fixed Scroll) and orbiting (Orbiting Scroll) involute scroll offset by 180° with zero metal-to-metal contact; sealing is maintained by replaceable dry polymer Tip Seals. Permanent magnet synchronous motors (PMSM) drive each air end directly on a single shaft (2800 rpm at 10 bar) with no belts or pulleys. Discharge air cools, enters the 300 L receiver, and flows through the integrated refrigerated dryer and filter before leaving the station.
2. Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Zhejiang Gaoling New Energy Technology Co., Ltd. (China) |
| Station Model | Gaoling L06Z-P110-10LR (All-in-One) |
| Scroll Air Ends | 2 × G06ZP (ZP Series, PM Direct Connection) |
| Air Purity Class | ISO 8573-1 CLASS 0 (TÜV Rheinland certified, 100% oil-free) |
| Rated Motor Power | 11 kW (5.5 kW × 2) / 15 HP |
| Motor Type | 2 × Permanent Magnet Synchronous Motor (PMSM) |
| Drive Type | Direct drive (beltless, coupling-free) |
| Power Supply | AC 380 V, 3-phase, 50 Hz (3N AC 380V 50Hz) |
| Rated Working Pressure | 1.0 MPa (10 bar) |
| Free Air Delivery (FAD, at 10 bar) | 1.0 m³/min (1000 L/min / 60.0 m³/h) |
| Air End Rated Speed | 2800 rpm (at 1.0 MPa) |
| Integrated Air Treatment | Refrigerated air dryer (LR) + line filter |
| Air Receiver Volume | 300 L |
| Air Outlet | G 1″ (BSPP female parallel thread) |
| Control System | Automatic pressure-sensitive control, MAM-860 controller (RS-485 / MODBUS-RTU) |
| Cooling System | Forced air cooling, Sirocco centrifugal fans |
| Condensate Drain | Automatic electronic drainage valve (standard) |
| Noise Level | 65 dB(A) |
| Dimensions (L × W × H) | 1652 × 700 × 1930 mm |
| Net Weight | 494 kg |
| Operating Ambient Temp / Humidity | 0 °C … +40 °C (recommended +5…+40 °C) / ≤ 80% |
| Manufacturer & Product Certifications | ISO 8573-1 CLASS 0 (TÜV Rheinland), CE (EN ISO 12100, EN 60204-1), ETL, ISO 9001, IATF 16949, ISO 14001, Class I Medical Instrument |
3. Design Features
Model Code Breakdown: L06Z-P110-10LR
| Code Element | Meaning | Explanation |
|---|---|---|
| L | Station Line | Gaoling oil-free scroll compressor stations |
| 06 | Air End Size | G06ZP scroll elements (5.5 kW each; 505 L/min per element at 10 bar) |
| Z | Drive Type | Direct drive (Direct Connection), vs. T for belt drive |
| P110 | Motors & Total Power | Permanent Magnet (PM) synchronous motors, 110 = 11.0 kW (5.5 kW × 2) |
| 10 | Working Pressure | 10 bar (1.0 MPa) |
| LR | All-in-One Package | Compressor + 300 L tank + refrigerated air dryer (LR) + filter (vs. LD with adsorption dryer) |
Key Engineering Solutions
- Dual Independent Direct-Drive
G06ZPModules (5.5 kW × 2): demand-based staging, balanced run-hour alternation, and 50% built-in redundancy inside a single footprint — with zero belt maintenance. - Factory-Piped All-in-One Package on a 300 L Receiver: scroll cabinet, refrigerated air dryer, and line filter come pre-plumbed and factory-tested on one frame — saving up to 40% compressor-room floor space and slashing on-site installation time.
- MAM-860 Microprocessor Controller: 4-line LCD display, automatic load/unload staging, phase-sequence protection (
PHASE PRO), high-temp protection (105 °C alarm / 110 °C trip), remote start/stop (LOCAL/REMOTE), MODBUS-RTU (RS-485) communications, andBLOCKnetwork cascading. - Sealed Air Path (
Tip Seal+Dust Seal): bearings remain isolated from compression chambers and are regreased via dedicated externalGrease Filling Ports. - Automatic Electronic Drain: discharges clean oil-free condensate automatically from the 300 L receiver and dryer separator.
4. Installation Guidelines
(Based on the official Gaoling Instruction Manual and Acvatron SRL engineering practice)
- Room & Ventilation: indoor installation only at +5…+40 °C (below 0 °C condensate freezes inside the refrigerated dryer heat exchanger and electronic drain) and relative humidity ≤ 80%. Because the combined 11 kW drive plus refrigerated dryer rejects substantial heat, dedicated intake/exhaust ventilation is essential. Leave at least 60–100 cm service clearance all around (intake on left, hot exhaust at rear).
- Foundation & Rigging: net weight is 494 kg, height 1930 mm. Place on a solid, level concrete slab strictly on the supplied rubber vibration isolators (
Rubber isolator) and remove all transport locking bolts before commissioning. - Electrical Connection (11 kW, AC 380 V, 3-Phase):
- Supply from 3N AC 380 V / 50 Hz through a dedicated circuit breaker with mandatory protective earthing (size cable and breaker for 2 × 5.5 kW plus the integrated refrigerated dryer).
- Verify phase sequence at first start-up (even with
MAM-860PHASE PROactive): reverse rotation exceeding 30 seconds can damage the scroll elements.
- Pneumatic Piping (G 1″ BSPP Outlet):
- The station air outlet is a G 1″ (BSPP) female parallel thread. Seal using a flat gasket or USIT / Bonded Seal washer — do not use PTFE tape (unlike tapered BSPT/R threads, which require PTFE tape, or metric parallel threads with a base O-ring).
- Connect to plant mains via a heat- and pressure-resistant flexible hose (for 10 bar machines, Section 2.3.1 of the manual requires > 1.2 MPa pressure rating, ≥ Ø25 mm internal diameter, > 150 mm bend radius, and > 100 °C heat resistance).
- Condensate Drainage: pipe drain lines from both the 300 L receiver electronic valve and the refrigerated dryer drain to a floor drain — oil-free condensate needs no oil-water separator.
- Safe Maintenance: isolate main power, depressurize to 0.00 MPa, and allow at least 30 minutes of natural cooling before servicing (never cool with water).
5. Equivalents and Comparison
Cross-Reference (11 kW / 10 bar Oil-Free Scroll Compressors)
| Manufacturer & Model | Power | Pressure | Flow (FAD) | Air Purity | Noise | Configuration Notes |
|---|---|---|---|---|---|---|
| Gaoling L06Z-P110-10LR | 11 kW (2×5.5) | 10 bar | 1000 L/min (1.0 m³/min) | ISO 8573-1 Class 0 (TÜV) | 65 dB(A) | All-in-One: dual PM blocks + 300 L tank + refrig. dryer + filter |
| Atlas Copco SF 11+ FF (10 bar) | 11 kW (15 HP) | 10 bar | 900 L/min (0.90 m³/min) | ISO 8573-1 Class 0 | 63 dB(A) | FF Full Feature with integrated refrigerated dryer |
| BOGE EO 11 D (10 bar) | 11 kW (2×5.5) | 10 bar | 980 L/min (0.98 m³/min) | ISO 8573-1 Class 0 | 59–65 dB(A) | Dual scroll + refrigerated dryer (D), optional receiver |
| Anest Iwata SLPE-1101E | 11 kW (3×3.7) | 10 bar | 1009 L/min (1.01 m³/min) | Oil-free (Scroll) | 60–62 dB(A) | Triple belt-driven multi-scroll, optional dryer (D) |
Important before substituting: verify footprint, whether a 300 L receiver is included (often sold separately by European brands), outlet thread (
G 1″), dryer dew point, and maintenance intervals.
Comparison Within the Gaoling All-in-One LR Lineup (01/2026 Catalog)
| Model | Power | Pressure | Flow (FAD) | Dryer / Tank | Outlet | Dimensions (mm) | Weight | Noise |
|---|---|---|---|---|---|---|---|---|
| L06Z-P55-8LR | 5.5 kW | 8 / 10 bar | 570 / 500 L/min | Refrig. dryer + 200 L | G 3/4″ | 1375 × 560 × 1518 | 267 kg | 65 dB(A) |
| L05Z-P75-8LR | 7.5 kW (3.7×2) | 8 / 10 bar | 760 / 700 L/min | Refrig. dryer + 300 L | G 1″ | 1652 × 700 × 1930 | 371 kg | 65 dB(A) |
| L06Z-P110-10LR | 11 kW (5.5×2) | 10 bar | 1000 L/min | Refrig. dryer + 300 L | G 1″ | 1652 × 700 × 1930 | 494 kg | 65 dB(A) |
| L06Z-P165-8LR | 16.5 kW (5.5×3) | 8 / 10 bar | 1710 / 1500 L/min | Refrig. dryer + 300 L | G 1″ | 2180 × 760 × 2380 | 590 kg | 69 dB(A) |
| L06T-Y110-8LR | 11 kW (5.5×2, belt) | 8 / 10 bar | 1140 / 1000 L/min | Refrig. dryer + 300 L | G 1″ | 1692 × 760 × 1934 | 495 kg | 68 dB(A) |
(Note: the direct-drive PM L06Z-P110-10LR runs 3 dB(A) quieter than the belt-driven L06T-Y110-8LR, takes less space, and requires zero belt replacements.)
Advantages over 11 kW oil-injected screw and oil-free piston compressors:
- vs. 11 kW Oil-Injected Screw: guaranteed Class 0 oil-free air with zero separator-breakthrough risk and without the 0.5–1.2 bar pressure loss of oil-removal/carbon filter cascades; zero oil, oil filter, separator, or oily-condensate disposal costs; staged 50% / 100% dual-scroll operation avoids idle power waste and oil emulsification.
- vs. Oil-Free Piston: true 24/7 duty at 10 bar without overheating, quiet 65 dB(A) operation (vs. 80–88 dB(A) for 11 kW pistons), pulsation-free air, and 5000 h
Tip Sealintervals vs. 1000–2500 h for PTFE piston rings.
6. Common Mistakes
- Installing an 11 kW + refrigerated dryer package in a tight, unventilated room. Heat rejected by two 5.5 kW motors and the dryer condenser quickly pushes room temperature above +40 °C — degrading dew point and tripping the
MAM-860high-temp alarm (110 °C). - Running the refrigerated dryer below +2…+5 °C. Water freezes inside the dryer heat exchanger and electronic drain, risking heat-exchanger rupture.
- Relying on the built-in refrigerated dryer (
LR) where GMP mandates −40 °C dew point. Refrigerated dryers operate physically above 0 °C (ISO 8573-1 Class 4). Direct contact with hygroscopic pharma powders or outdoor winter lines requires an adsorption dryer (LDversion or external desiccant dryer). - Servicing only one air end or skipping the 5000 h overhaul (
Tip Seal+ bearing grease). BothG06ZPmodules require scheduled care: filter cleaning at 400 h and 1500 h, filter replacement at 2500 h / 1 year, andTip Sealreplacement + bearing regreasing at 5000 h / 2 years. - Using an undersized (< Ø25 mm) or under-rated discharge hose. For a 10 bar / 1000 L/min station, Section 2.3.1 mandates ≥ Ø25 mm I.D. and > 1.2 MPa hose rating.
- Neglecting condenser and air-cooler dust cleaning. Dust-fouled dryer condenser fins reduce cooling capacity and allow moisture carryover downstream.
7. Applications (Exact Engineering Sizing at 1000 L/min, 10 bar)
At 1000 L/min (60.0 m³/h) at 10 bar, the continuous design load with a 20–25% engineering margin is 750–800 L/min of pre-dried, 100% oil-free compressed air.
Industry Sizing Table
| Industry & Equipment | Typical Demand per Unit (Benchmarks) | Capacity of L06Z-P110-10LR (1000 L/min, 10 bar) |
Additional Notes |
|---|---|---|---|
| Large Dental Clinic / Medical Center (Chairs) | 50–60 L/min per active chair at 5 bar (ISO 7494 / Dürr Dental / Cattani; 70+ L/min with Air-Flow / CAD/CAM) | 13–15 chairs simultaneously (with 20–25% margin) → 16–20 installed chairs (0.70–0.75 coincidence factor). Built-in 50% backup (500 L/min on one air end) | Refrigerated dryer is built in (LR); add an ISO 22052 bacterial/sterile filter |
| Pharmaceutical (GMP): Blister, Capsule & Dedusting Lines | Deduster: 50–200 L/min; capsule filler: 300–800 L/min; blister line: 400–1200 L/min (6–7 bar) | 1 high-output blister or capsule machine (up to ~750–800 L/min) or 1 capsule filler + 2–3 dedusters simultaneously | For direct drug contact under GMP: add adsorption dryer (−40…−70 °C PDP) + 0.01 µm sterile filters & 316L piping |
| PSA Nitrogen Generators (Wineries, MAP Packaging, Electronics) | Air-to-N₂ ratio ~3–4:1 at 99–99.5% N₂ purity and 8–10 bar | Feeds a PSA generator rated up to ~220–280 L/min N₂ (13–17 m³/h N₂) | Dry Class 0 air straight from the station; match dew point for 99.99% N₂ units |
| Small PET Blowing, CNC Clamping & Laser Cutting (8.5–9.5 bar) | High-pressure actuators, optics purging, forming stations | Holds steady 8.5–9.5 bar at point of use up to 750–800 L/min despite line drops | Add fine particulate filtration per machine OEM spec |
| Food Processing & Winemaking | Bottling, capping, labeling, pneumatic conveying | 2–3 production lines totaling 750–800 L/min | Turnkey package (300 L tank + dryer + filter built in) |
When Not Recommended
- Continuous demand above 850–900 L/min at 10 bar: step up to the triple-scroll All-in-One
L06Z-P165-8LR(16.5 kW, 1500 L/min at 10 bar) or modularL06Z-P220-8/L06Z-P330-8stations. - 8 bar plants prioritizing maximum flow at 11 kW: the 8 bar
L06Z-P110-8LRdelivers 1140 L/min (+140 L/min). - Sub-freezing spaces (< +2 °C) or chemically aggressive/explosive environments.
8. Expert Opinion
Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience: “The Gaoling L06Z-P110-10LR is a complete central clean-air plant in one footprint: two independent 5.5 kW G06ZP scroll modules, a 300 L receiver, a refrigerated dryer, and a line filter. For a 16–20 chair dental center, a pharmaceutical packaging room, or a winery running a PSA nitrogen generator, the real value goes beyond its verified 1000 L/min at 10 bar and TÜV Rheinland Class 0 certificate — it is built-in redundancy. Take one air end offline for maintenance and the second keeps feeding 500 L/min without stopping operations. Just make sure the compressor room has proper exhaust ventilation for 11 kW plus dryer heat, and let us add a desiccant dryer and sterile filtration if your GMP protocol specifies −40 °C dew point.”
9. FAQ
1. Why are two 5.5 kW air ends better than a single 11 kW compressor? Two independent G06ZP blocks deliver staged 50% / 100% power savings at partial load and 50% built-in redundancy: during maintenance or a fault on one unit, the second keeps supplying 500 L/min at 10 bar so the clinic or plant never goes down.
2. How many dental chairs can the Gaoling L06Z-P110-10LR run? At 50–60 L/min per chair at 5 bar with a 20–25% engineering margin, it powers 13–15 chairs simultaneously, covering a large 16–20 chair dental clinic at a 0.70–0.75 coincidence factor (refrigerated dryer is built in; add an ISO 22052 bacterial filter).
3. Do I need an extra dryer if the L06Z-P110-10LR already includes a refrigerated dryer? For dental clinics, food/wine lines, CNC, and indoor automation, the built-in LR refrigerated dryer is sufficient. An additional adsorption dryer (−40 °C to −70 °C PDP) is only needed for direct GMP contact with hygroscopic pharmaceuticals or outdoor winter piping.
4. What is the maintenance schedule for the Gaoling L06Z-P110-10LR? Daily condensate/drain check; air filter dust cleaning at 400 h and 1500 h; air filter replacement, cooler cleaning, and valve/sensor inspection at 2500 h / 1 year; Tip Seal replacement and bearing regreasing on each block every 5000 h / 2 years; rubber isolators and safety relief valve replacement at 10,000 h / 4 years.
5. What is the difference between L06Z-P110-10LR and L06Z-P110-8LR? Both share the same chassis (2 × 5.5 kW, 300 L tank, refrigerated dryer, 494 kg, 65 dB(A)). The 10LR runs at 10 bar (2800 rpm) delivering 1000 L/min, while the 8LR runs at 8 bar delivering 1140 L/min.


Reviews