Gaoling L05Z-P37-8SC Oil-Free Scroll Compressor (3.7 kW, 8 bar, 400 L/min, 120 L)

The Gaoling L05Z-P37-8SC is a versatile stationary 3.7 kW (5 HP) oil-free scroll air compressor with a direct-drive permanent magnet synchronous motor (PMSM), mounted on a 120 L horizontal air receiver. Set for standard 8 bar (0.8 MPa) working pressure, it delivers 400 L/min (0.40 m³/min / 24.0 m³/h) of 100% oil-free compressed air certified to ISO 8573-1 CLASS 0 (TÜV Rheinland).

6 People watching this product now!
Description

1. Purpose and Operating Principle

Compared with the 10 bar L05Z-P37-10SC, the 8SC delivers +50 L/min more air from the exact same 3.7 kW motor and 800 × 560 × 1453 mm footprint. It is the ideal choice for mid-sized dental clinics (6–8 chairs), analytical laboratories, small pharmaceutical rooms, food processing, and wineries where point-of-use pressure stays under 6–7.5 bar and higher flow matters most.

Compression principle (G05ZP scroll air end): No lubricating oil exists anywhere in the G05ZP compression chamber. Air is compressed smoothly and continuously by two precision involute scrolls — one stationary (Fixed Scroll) and one orbiting (Orbiting Scroll) offset by 180° — operating with zero metal-to-metal contact and sealed by replaceable polymer Tip Seals. In the ZP series, the permanent magnet synchronous motor rotor and scroll element share a single shaft (direct drive, 3000 rpm at 8 bar) with no V-belts or pulleys. Control, diagnostics, and safety protections are managed by the MAM-860 microprocessor controller with RS-485 / MODBUS-RTU and BLOCK cascade networking.


2. Technical Specifications

Parameter Value
Manufacturer Zhejiang Gaoling New Energy Technology Co., Ltd. (China)
Station Model Gaoling L05Z-P37-8SC
Scroll Air End G05ZP (ZP Series, PM Direct Connection)
Air Purity Class ISO 8573-1 CLASS 0 (TÜV Rheinland certified, 100% oil-free)
Rated Motor Power 3.7 kW (5 HP)
Motor Type Permanent Magnet Synchronous Motor (PMSM)
Drive Type Direct drive (beltless, coupling-free)
Power Supply AC 380 V, 3-phase, 50 Hz
Required Cable Size / Rated Current 2.5 mm² (Ø1.8 mm) / 25 A (Instruction Manual, Table 1)
Working Pressure (Adjustment Range) 0.8 MPa / 8 bar (factory setting: load 0.60 MPa / unload 0.80 MPa)
Free Air Delivery (FAD, at 0.8 MPa) 0.40 m³/min (400 L/min / 24.0 m³/h)
G05ZP Air End Rated Speed 3000 rpm (at 0.8 MPa)
Air Receiver Volume 120 L
Station Air Outlet G 1/2″ (BSPP female parallel thread)
G05ZP Air End Outlet Rp 3/8″ (internal thread, inside canopy)
Controller MAM-860 microprocessor controller (LCD, RS-485 / MODBUS-RTU, Master/Slave cascade)
MAM-860 Protection Setpoints Over-temp: alarm 105 °C / trip 110 °C; over-pressure: trip 1.00 MPa; phase protection (PHASE PRO)
Cooling System Forced air cooling, Sirocco centrifugal fan
Condensate Drain Automatic electronic drainage valve (standard)
Noise Level 65 dB(A)
Station Dimensions (L × W × H) 800 × 560 × 1453 mm
G05ZP Air End Dimensions / Weight 500 × 355 × 312 mm / 40 kg
Net Weight 174 kg
Operating Ambient Temp / Humidity 0 °C … +40 °C (recommended +2…+40 °C) / ≤ 80%
Manufacturer & Product Certifications ISO 8573-1 CLASS 0 (TÜV Rheinland), CE (EN ISO 12100, EN 60204-1), ETL, ISO 9001, IATF 16949, ISO 14001, Class I Medical Instrument

3. Design Features

Model Code Breakdown: L05Z-P37-8SC

Code Element Meaning Explanation
L Station Line Gaoling oil-free scroll compressor stations
05 Air End Size G05ZP scroll element (3.7 kW nominal; 400 L/min at 8 bar / 350 L/min at 10 bar)
Z Drive Type Direct drive (Direct Connection), vs. T for belt drive
P37 Motor & Power Permanent Magnet (PM) synchronous motor, 37 = 3.7 kW
8 Working Pressure 8 bar (0.8 MPa)
SC Configuration Direct-drive PM station in acoustic canopy on a 120 L air receiver

Key Engineering Solutions

  • ZP Series Direct-Drive PM (G05ZP): PMSM motor and scroll air end share one shaft — net weight is 174 kg (56 kg lighter than the belt-driven L05T-Y37-8XC), eliminating belt slip, tension checks, and belt replacements.
  • MAM-860 Microprocessor Controller: 4-line LCD monitoring pressure, discharge temperature, supply voltage, and service timers; built-in phase-sequence protection (PHASE PRO), remote start/stop (LOCAL/REMOTE), MODBUS-RTU (RS-485), and BLOCK Master/Slave networking (up to 16 units).
  • Sealed Oil-Free Air Path (Tip Seal + Dust Seal): dry polymer tip seals keep compression oil-free, while a dust barrier and external Grease Filling Port isolate bearing grease from the air stream.
  • Standard Automatic Electronic Drain: purges clean water condensate from the 120 L receiver automatically to prevent tank corrosion and downstream moisture carryover.
  • Directed Sirocco Air Cooling: left-side air intake and rear hot-air exhaust enable continuous 24/7 operation.

4. Installation Guidelines

(Based on the official Gaoling Instruction Manual and Acvatron SRL engineering practice)

  1. Room & Clearances: indoor installation only — clean, dry, ventilated room at +2…+40 °C (manual specifies 0…+40 °C; above +2 °C prevents drain freezing) and humidity ≤ 80%. Maintain at least 60 cm clearance all around (intake on left, hot exhaust at rear; ≥ 60 cm between adjacent compressors).
  2. Floor & Vibration Mounts: install on a solid, level floor strictly on the rubber isolators (Rubber isolator), and remove all transport locking bolts/pins before commissioning.
  3. Electrical Wiring (3.7 kW, AC 380 V, 3-Phase):
    • Connect to AC 380 V / 3-phase / 50 Hz with mandatory protective earthing.
    • Per Table 1 of the manual, 3.7 kW requires at least a 2.5 mm² copper cable (Ø1.8 mm) and a 25 A rated breaker.
    • Verify phase sequence on initial start-up (even with MAM-860 PHASE PRO enabled): reverse rotation over 30 seconds can damage the scroll air end.
  4. Pneumatic Line Connection (G 1/2″ BSPP):
    • Seal the G 1/2″ (BSPP) female parallel outlet with a flat gasket or USIT / Bonded Seal washer — do not use PTFE tape (unlike tapered BSPT/R threads, which use PTFE tape, or metric parallel threads with a base O-ring).
    • Connect via a heat- and pressure-resistant flexible hose (Section 2.3.1: ≥ Ø25 mm internal diameter, > 150 mm bend radius, > 1.0 MPa pressure rating, > 100 °C heat resistance).
  5. Drying & Filtration: Class 0 removes oil, not moisture. For dental clinics (ISO 22052), labs, and pharma, install a refrigerated (+3 °C) or adsorption (−20 °C / −40 °C) dryer and particulate/bacterial filtration downstream of the 120 L receiver.
  6. Safe Service: open the outlet shut-off valve before starting; after > 1 month idle, clean dust and run a 1-minute test. Before maintenance, isolate power, depressurize to 0.00 MPa, and allow at least 30 minutes of natural cooling (never cool with water).

5. Equivalents and Comparison

Cross-Reference (3.7–4.0 kW / 8 bar Oil-Free Scroll Compressors)

Manufacturer & Model Power Pressure Flow (FAD) Air Purity Noise Configuration Notes
Gaoling L05Z-P37-8SC 3.7 kW (5 HP) 8 bar 400 L/min (0.40 m³/min) ISO 8573-1 Class 0 (TÜV) 65 dB(A) Direct-drive PM, 120 L tank, electronic drain, MAM-860
Atlas Copco SF 4 (8 bar) 3.7 kW (5 HP) 8 bar 400–410 L/min ISO 8573-1 Class 0 53–58 dB(A) Pack / FF (integrated dryer), opt. 270 L tank
BOGE EO 4 (8 bar) 4.0 kW (5.5 HP) 8 bar 410 L/min (0.41 m³/min) ISO 8573-1 Class 0 60 dB(A) Base cabinet, receiver (R), or dryer (D)
Anest Iwata SLPE-37E (8 bar) 3.7 kW (5 HP) 8 bar 404 L/min Oil-free (Scroll) 59 dB(A) Belt drive, stationary enclosure
Remeza KS5-8 / KS5-8-270 4.0 kW 8 bar 410 L/min Oil-free (Scroll) 63 dB(A) Frame (КС5-8) or 270 L tank (КС5-8-270), opt. M/D dryers

Important before substituting: verify receiver volume, dimensions, outlet thread (G 1/2″), dryer integration, and service intervals.

Comparison Within the Gaoling Lineup (01/2026 Catalog)

Model Drive Power Pressure Flow (FAD) Tank Outlet Weight Noise
L02Z-P30-8SC Direct PM 3.0 kW 8 bar 300 L/min 120 L G 1/2″ 171 kg 65 dB(A)
L05Z-P37-8SC Direct PM 3.7 kW 8 bar 400 L/min 120 L G 1/2″ 174 kg 65 dB(A)
L05Z-P37-10SC Direct PM 3.7 kW 10 bar 350 L/min 120 L G 1/2″ 174 kg 65 dB(A)
L06Z-P55-8SC Direct PM 5.5 kW 8 bar 600 L/min 120 L G 1/2″ — 63 dB(A)*
L05T-Y37-8XC Belt 3.7 kW 8 bar 400 L/min 120 L G 1/2″ 230 kg 65 dB(A)
L05Z-P37-8SM Direct PM 3.7 kW 8 bar 370 L/min 5 L + membrane dryer G 1/2″ 117 kg 65 dB(A)

(Compared with the belt-driven L05T-Y37-8XC, the direct-drive PM L05Z-P37-8SC is 56 kg lighter and eliminates belt maintenance.)

Advantages over 3.7–4 kW oil-injected screw and oil-free piston compressors:

  • vs. Oil-Injected Screw: guaranteed ISO 8573-1 CLASS 0 air with zero separator-breakthrough risk; eliminates oil, oil filters, separators, and oily-condensate disposal; runs cleanly across 0–100% variable demand without oil emulsification.
  • vs. Oil-Free Piston (PTFE): true 24/7 continuous duty without cooling stops, far quieter (65 dB(A) vs. 75–85 dB(A)), pulsation-free flow, and 5000 h Tip Seal service life vs. 1000–2500 h for PTFE piston rings.

6. Common Mistakes

  1. Buying the 8 bar build for 8–9 bar equipment with line pressure drops. If tools require 8+ bar after dryers and filters, choose the 10 bar L05Z-P37-10SC.
  2. Sizing a dental clinic to the full 400 L/min without a 20–25% margin. With 7–8 active chairs or Air-Flow / CAD/CAM loads, pressure will sag — for 9+ chair clinics step up to L06Z-P55-8SC (600 L/min).
  3. Starting without phase verification or with undersized wiring/breaker. Per Table 1, 3.7 kW (380 V) mandates ≥ 2.5 mm² cable and a 25 A breaker, and reverse rotation over 30 seconds damages the G05ZP air end.
  4. Skipping the 2500 h air filter change or 5000 h Tip Seal + bearing grease overhaul. Per Table 5, blow off the filter at 400 h and 1500 h, replace it at 2500 h / 1 year, and replace Tip Seals + add fresh bearing grease strictly at 5000 h / 2 years.
  5. Expecting dry air without adding a dryer. Class 0 removes oil, not water vapor — install a downstream dryer for dental, lab, and pharma sites.
  6. Threading a tapered fitting (R 1/2″ / NPT 1/2″) into the parallel G 1/2″ (BSPP) port. Use only a G 1/2″ male fitting with a flat gasket / Bonded Seal and no PTFE tape.

7. Applications (Exact Engineering Sizing at 400 L/min)

At 400 L/min (24.0 m³/h) at 8 bar, the continuous design load with a 20–25% engineering margin (covering filter/piping drops and dryer losses) is 300–320 L/min.

Industry Sizing Table

Industry & Equipment Typical Demand per Unit (Benchmarks) Capacity of L05Z-P37-8SC (400 L/min, 8 bar) Required Downstream Treatment
Dental Clinic (Dental Chairs / Units) 50–60 L/min per active chair at 5 bar (ISO 7494 / Dürr Dental / Cattani; 70+ L/min with Air-Flow / CAD/CAM) 5–6 chairs simultaneously (with 20–25% margin) → 6–8 installed chairs (0.65–0.75 coincidence factor; or 5–6 chairs with active Air-Flow / CAD/CAM) Air dryer (≤ +3 °C or −20 °C PDP) + ISO 22052 bacterial/particulate filter
Pharmaceutical (GMP): Dedusting & Filling Tablet deduster: 50–200 L/min (4–6 bar); compact capsule filler: from 300 L/min 1–2 tablet dedusters simultaneously or 1 compact capsule / filling machine (up to ~300–320 L/min) Adsorption dryer (−40…−70 °C PDP) + 0.01 µm sterile filters & 316L piping
Laboratories & PSA Nitrogen Generators Chromatographs/analyzers: 10–30 L/min; PSA N₂ (99–99.5%): ~3–4:1 air-to-N₂ ratio 10–15 lab instruments or a PSA nitrogen generator up to ~80–110 L/min N₂ Air dryer + fine particulate line filter
Food, Winemaking & HVLP Spraying Bottling/capping/MAP line, 1 oil-free HVLP spray gun (250–300 L/min) 1 production line or 1 clean-air spray booth totaling 300–320 L/min Refrigerated dryer (+3 °C) + particulate filter
  • Dental clinics with 9–10+ chairs or demand above 350 L/min: upgrade to L06Z-P55-8SC (5.5 kW, 600 L/min — 10–12 chairs) or L06Z-P110-10LR (11 kW, 1000 L/min — 16–20 chairs).
  • Processes requiring 8.5–9.5 bar: select the 10 bar L05Z-P37-10SC (350 L/min at 10 bar).
  • Unheated (< +2 °C) or heavily dusty rooms.

8. Expert Opinion

Vitali Boluchevski, Lead Engineer, Acvatron SRL, 18 years of experience: “The Gaoling L05Z-P37-8SC is the most balanced unit in the 120 L SC series. From a 3.7 kW motor it delivers a verified 400 L/min of Class 0 oil-free air (+50 L/min over the 10 bar version), comfortably powering a full 6–8 chair dental clinic, a busy analytical lab, or a bottling/packaging line with proper engineering headroom. Direct PM drive shaves 56 kg off the belt-driven version and removes belt service altogether, while the MAM-860 controller handles phase monitoring, service hours, and future RS-485 cascading.”


9. FAQ

1. How many dental chairs can the Gaoling L05Z-P37-8SC support? At 50–60 L/min per active chair at 5 bar, its 400 L/min output with a 20–25% safety margin supports 5–6 chairs simultaneously, covering a 6–8 chair dental clinic at a 0.65–0.75 coincidence factor (paired with an external ISO 22052 dryer and filter).

2. What is the difference between L05Z-P37-8SC and L05Z-P37-10SC? Both share the same 3.7 kW G05ZP air end and 120 L receiver (174 kg, 65 dB(A)). The 8SC runs at 8 bar (3000 rpm) delivering 400 L/min, while the 10SC runs at 10 bar (2800 rpm) delivering 350 L/min. For dental clinics and 6–7 bar machinery, 8SC gives +50 L/min extra capacity.

3. What cable size and circuit breaker are needed for 3.7 kW (380 V)? Per Table 1 of the official Gaoling Instruction Manual, 3.7 kW (AC 380 V / 50 Hz) requires at least a 2.5 mm² copper cable (Ø1.8 mm), a 25 A breaker, and mandatory grounding.

4. What is the official maintenance schedule for the Gaoling L05Z-P37-8SC? Per Table 5: daily condensate drain; air filter dust blow-off at 400 h and 1500 h; air filter replacement and valve/sensor inspection at 2500 h / 1 year; Tip Seal replacement and bearing regreasing at 5000 h / 2 years; rubber isolators and safety relief valve replacement at 10,000 h / 4 years.

5. Do I need a separate air dryer for the L05Z-P37-8SC? Yes, if your application needs dry air (dental, labs, pharma, CNC). ISO 8573-1 CLASS 0 guarantees oil-free air, not moisture removal; pair the 120 L receiver with a refrigerated (+3 °C) or adsorption (−20 °C / −40 °C) dryer.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Gaoling L05Z-P37-8SC Oil-Free Scroll Compressor (3.7 kW, 8 bar, 400 L/min, 120 L)”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.